4 Core XLPE Insulated Aerial Bundled Cable For Overhead Distribution Lines

Ask Latest Price
Brand Name :SHANCABLE
Model Number :ABC
Certification :CE ROHS KEMA
Place of Origin :Shanghai ,China
MOQ :1000m
Price :0.19-10.99USD/M
Payment Terms :L/C, T/T
Supply Ability :500km per Month
Delivery Time :15 Days
Packaging Details :Wooden Drum/ Steel Drum
Rated Voltage :0.6/1kV
Color :Black
Main Usage :Overhead fixed layout and wire conducting
Insulation :PVC or XLPE
Package :Wooden drum
Original :CHINA
Core :3.4.5
Use :Overhead Distribution Lines
Corporation :shenghua group
Brand :Sh Cable
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

4Core With XLPE Insulated Aerial Bunch Cable For Overhead Distribution Lines

Specifications

To supply power from the utilitys lines to the consumers weatherhead.For service at 600 volts or less(phase to phase).

Aerial Bundled Cable is a new type aeral bundled cable used for transmitting electric power overhead.

Standards

1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Applications

To supply power from the utilitys lines to the consumers weatherhead.For service at 600 volts or less(phase to phase) at a conductor temperature of 75oC maximum for polyethylene insulation or 90 oC maximum for crosslinked insulation.

Construcrtion

1.stranded aluminium conductor

2.PE or XLPE insulation

3.ACSR, AAAC,Galvanised steel wire Messenger wire
3 power cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor

Technical Data:
Maksimum operating temperature 90 degree
Maximum short-circuit temperature 250 degree.Service drop( ABC cables) are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like village.

Classification

1. Duplex Service Drop

Primary used for 120 volt overhead service application such as street lighting, outdoor lighting, and temporay service for construction. To be used at voltages of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.

2.Triplex Service Drop

Used to supply power, usually from a pole-mounted transformer to the user's service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.

3. Quadruplex Service Drop

Used to supply 3 phase power, usually from a pole-mounted transformer to the user's service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.

Schedule of technical particulars

Phase conductor
Nominal cross-sectional area mm² 25 35 50 70 95 120 150 185
Number of cores 3 3 3 3 3 3 3 3
Minimum number of wires 6 6 6 12 15 15 30 30
Nominal insulation thickness mm 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0
Diameter of insulated core mm 8.5 9.5 11.2 13.0 15.1 16.6 18.4 20.6
Max. DC resistance at 20℃ ohm/km 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164
Current rating at still wind, ambient A 84 104 129 167 209 246 283 332
temperature=30℃
Conductor temperature=75℃
Messenger conductor
Nominal cross-sectional area mm² 25 25 35 50 70 70 95 120
Minimum number of wires 6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Calculated breaking load kN 6.4 6.4 8.9 12.1 18.0 18.0 24.2 30.8
Street lighting conductor
Nominal cross-sectional area mm² 25 25 35 50 70 70 95 120
Minimum number of wires 6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Completed cable
Approx. overall diameter mm 23.2 25.6 30.0 34.9 40.6 44.1 49.2 54.9
Approx. weight of cable kg/km 470 560 740 980 1330 1580 1940 2410
Packing length m/drum 1000 1000 1000 1000 500 500 500 500